Energy Manager EM410 Compact automation at Home for detached houses.

EM410
  • Application for detached and semi-detached houses (4-quadrant meter, class 1, 4 DU)
  • Energy automation based on EEBus
  • Modular energy automation (white goods, inverter, battery, heat pump, charging station)
  • 63 A direct measurement
  • Scheduling and prioritizing, static and dynamic tariff
  • Data logging (UI w/ & w/o cloud) cloud updates
Integrated 3-phase energy measuring up to 63 A
Connect up to 96 external power sensors via RS485
Integrated Linux system
Compact current sensors for easy installation. Easy implementation of an energy monitoring system with sensorbars and energy manager

Operating conditions

Max. Height during operation:
  • 2000m above NN
Storage temperature:
  • -25°C…+60°C
Ambient temperature:
  • -25°C...+45°C

Operating System

Operating System:
  • Embedded Linux with integrated TCP/IP Stack

Personal consumption

Voltage path:
  • < 0.01 VA per phase
Current path:
  • < 2 VA per phase
Complete device:
  • < 5 W without activated WLAN
Limiting current:
  • 63 A
Nominal current:
  • 5 A
Starting current:
  • < 25mA

Mechanical data

Housing material:
  • Glass fibre reinforced polyamide
Glow wire test:
  • Text according to IEC 695-2-1
Protection class/type:
  • II/IP2X
Size:
  • 88x70x65 mm
Weight:
  • 0.3 kg

Measurement accuracy

Voltage:
  • +/- 0.5%
Current:
  • +/- 0.5%
Active power:
  • +/- 1.0%
Apparent power:
  • +/- 1.0%
Reactive power:
  • +/- 1.0%
Power factor:
  • +/- 1.0%
Definition:
  • Related to IEC 62053-22 or -23 (typical)
Active energy:
  • Class 1
Reactive energy:
  • Class 1
Note:
  • Note: When using external current transformers, the respective measuring accuracy must be taken into account.

Assembly

Wire size:
  • 10-25 mm² (Mechanical: from 1.5-25 mm²)
Torque for screw terminal:
  • 2.0 Nm

Product norms

EN 61010:
  • yes
EN 50428:
  • yes
EN 60950:
  • yes

CPU/Processor data

CPU/Processor:
  • ARM9 processor mit 450 MHz, DDR2 RAM mit 128 Mbyte eMMC Flash 4 Gbyte

Interfaces

LAN:
  • 10/100 Mbit
RS485:
  • 2x Half-Duplex, max. 115200 Baud

Voltage and current inputs

Rated voltage:
  • max. 230/400 V~ (without WLAN), 230/400 V~ (with WLAN)
Operating voltage:
  • 110/230 V~ V +/-10% (without WLAN), 230 V~ V +/-10% (with WLAN)
Frequency:
  • 50/60Hz +/-5%
-1